Skip to main content

Heat Transfer Compounds

Efficient thermal connection
Image
SnapTrace

A steam tracer installed with Heat Transfer Compound has the equivalent heat output of 3 to 6 bare tracers. Fewer steam traps to maintain and a quicker, cost effective installation. A bare tracer heats air to heat the pipe. A tracer installed with Heat Transfer Compound, directly heats the pipe. 

Heat Transfer Compound offer full flexibility and provide an efficient thermal connection between the tracer and the heated object.

Whether:

  • bonding tracer tubing to long piping runs
  • irregular surfaces (valves and pumps) or
  • tank walls

there is a Heat Transfer Compound specifically designed for every trace heating application.

SnapTrace is a preformed flexible heat transfer compound designed for straight piping runs, 1-1/2 inches (38 mm) and larger. SnapTrace includes TFK galvanized channel, providing mechanical and weather protection.

A single SnapTrace is available in 4' long sections to fit on piping without any problems.

Advantages of Preformed Flexible Heat Tracing Compound
  • Easy, fast installation (snap-on)
  • No curing procedure required
  • Factory-formed to fit tracer and pipe (1.22m sections)
  • No surface preparation required
  • Non-soluble in water
Image
Steam Trace HTC Channel
Thermon SnapTrace
Image
SnapTrace Preformed Steam Tracing Heat Transfer Compound

Max Exposure Temperature: 232ºC

Water Soluble: No

Curing: No

*piping *freeze protection *low - medium process temperature maintenance 

Download SnapTrace datasheet

 

Thermon T-3
Image
T-3 Steam Trace Heat Transfer Compound

Max Exposure Temperature: 454ºC

Water Soluble: Yes

Curing: Not required with use of TFK Channels

*piping *freeze protection *low - medium process temperature maintenance 

Download T-3 datasheet

 

Thermon T-99
Image
T-99 Steam Trace Heat Transfer Compound

Max Exposure Temperature: 1204ºC

Water Soluble: Yes

Curing: Not required with use of TFK Channels

*piping *freeze protection *high process temperature maintenance 

Download T-99 datasheet

 

Thermon T-85
Image
T-95 Steam Trace Heat Transfer Compound

Max Exposure Temperature: 232ºC

Water Soluble: No

Curing: Self curing in 4-12 hours

*valves, pumps & instruments *freeze protection *low - medium process temperature maintenance 

Download T-85 datasheet

 

Thermon NH
Image
NH-1 Steam Trace Heat Transfer Compound

Max Exposure Temperature: 210ºC

Water Soluble: No

Curing: Self curing in 4-12 hours

*For Coils & Plate heaters on Tanks, vessels & other equipment *freeze protection *low process temperature maintenance 

Download NH datasheet